A certificate of analysis is only as useful as your ability to read it. For a seven-residue peptide like Semax, three numbers carry most of the weight: identity, purity and net content. Here is what each one means, how the instruments produce it, and where the common ambiguities hide.
Know the compound before you check the paperwork
Semax is a synthetic linear heptapeptide. Its reference identifiers are worth having in front of you when a COA lands:
- Sequence: Met-Glu-His-Phe-Pro-Gly-Pro (one-letter code MEHFPGP)
- CAS number: 80714-61-0
- Molecular formula: C37H51N9O10S
- Molecular weight: 813.92 g/mol, free base
- PubChem CID: 122178
- Appearance: white to off-white lyophilized powder
Catalogs also list the sequence descriptively, as “ACTH(4–7)-Pro-Gly-Pro” or “[Pro8,Gly9,Pro10]ACTH(4–10),” because the first four residues correspond to positions 4 through 7 of adrenocorticotropic hormone. Different names, same seven residues. If a document uses one of those forms, it is not describing a different material.
Identity: what mass spectrometry confirms
Identity on a peptide COA is normally established by liquid chromatography coupled to mass spectrometry. The chromatograph separates the sample in time; the mass spectrometer measures the mass-to-charge ratio of what comes off the column.
For a molecule of this size the expected singly protonated ion sits near m/z 814.9, with the doubly charged species near 408. A matching mass is strong evidence that the main peak is the intended compound rather than a different peptide of similar polarity.
Two caveats are worth keeping in mind. First, mass confirms composition, not order: two peptides built from the same residues in a different sequence share a molecular weight. Confirming order requires fragmentation data (MS/MS) or sequencing. Second, a reported mass that is tens of daltons off is not a rounding difference. It usually points to a truncation, an oxidation or a different salt form.
Methionine deserves a second look
Semax carries a methionine at position one, and methionine’s thioether sulfur is the most readily oxidized group in the molecule. Oxidation to the sulfoxide adds 16 daltons and typically shifts retention time. A COA showing a clean single peak and the expected parent mass is, among other things, evidence that this has not happened to any meaningful extent.
Purity: a percentage with an asterisk
Purity on a peptide COA is almost always HPLC area percent: the area of the main peak divided by the total area of all detected peaks, usually with UV detection around 214 nm, where the peptide bond absorbs.
That definition carries a quiet limitation. Area percent only counts what the detector sees and the column resolves. Residual solvent, water and counterions are generally invisible at 214 nm, so an HPLC purity figure is a statement about peptide-related impurities, not a mass balance of the vial. Commercial reference standards of Semax are commonly supplied as a salt, often the trifluoroacetate or acetate, and that counterion contributes mass without contributing peak area.
Related impurities in a synthetic heptapeptide tend to fall into predictable families: deletion sequences from an incomplete coupling step, truncated chains, and oxidized or otherwise modified variants. A good method separates these from the main peak rather than hiding them under it, which is why the chromatogram itself matters as much as the number printed above it.
What to look for in the trace
- A flat, stable baseline rather than a drifting or noisy one.
- A symmetrical main peak. Pronounced shouldering can mean two species are co-eluting.
- A gradient long enough that the main peak is not crowded against the injection front.
- Named analytical methods, a lot number and a report date, not just a summary figure.
Net content, and why it rarely matches the label exactly
Net content is the measured mass of material in the container. Lyophilized peptides are typically filled with a deliberate overage, because some loss during filling and freeze-drying is unavoidable and an underfilled vial is the worse outcome. A measured value slightly above the nominal label size is normal and expected; a value below it is the one that should prompt questions.
For reference, our most recent Semax 5 mg lot, GBBM-SX-036, was tested by Freedom Diagnostics in May 2026 under accession 2605010199. Identity was confirmed as Semax by LC-MS, purity was reported at 99.74% by HPLC-UV, and the appearance was recorded as a white lyophilized powder. The full certificate accompanies the lot.
Handling the material in the lab
Reference suppliers specify storage of the lyophilized powder at −20 °C, kept dry and protected from light. Two practices follow from the chemistry above.
Let a sealed vial reach room temperature before opening it. Cold glass condenses atmospheric moisture, and a hygroscopic powder will take that water up. Second, minimize headspace air exposure and repeated freeze-thaw cycles, both of which favor oxidation at the methionine residue.
Semax is documented as water soluble, with reference solubility above 2 mg/mL in water. Any in-vitro work should follow your own laboratory’s validated protocols for preparation, concentration verification and solution storage.
The gold standard is the one you can verify
A purity figure with no lot number, no method and no chromatogram is a marketing claim. A figure tied to all three is data. Every lot we ship carries third-party analysis, and we would rather you read the chromatogram than take our word for it.
View our Semax listing and its testing documentation, or browse the full catalog of research materials.